Skip to main content
Open Smart Grid - OpenSG
Login | Join | Help (new window)


Open Smart Grid - OpenSG > Help Desk > Service Requests > Modify UsagePoint/RoleFlags to match SEP2  

Service Requests: Modify UsagePoint/RoleFlags to match SEP2

Version HistoryVersion History

Service Request

Modify UsagePoint/RoleFlags to match SEP2 

Details

SEP2 specifies the following bit-field definitions. ESPI should map one-to-one to this list. ESPI has shifted the bit fields by one bit and SEP also has an additional item defined. Bit 0 - isMirror - SHALL be set if the server is not the measurement device Bit 1 - isPremisesAggregationPoint - SHALL be set if the UsagePoint is the point of delivery for a premises Bit 2 - isPEV - SHALL be set if the usage applies to an electric vehicle Bit 3 - isDER - SHALL be set if the usage applies to a distributed energy resource, capable of delivering power to the grid. Bit 4 - isRevenueQuality - SHALL be set if usage was measured by a device certified as revenue quality Bit 5 - isDC - SHALL be set if the usage point measures direct current Bit 6 - isSubmeter - SHALL be set if the usage point is not a premises aggregation point Bit 7-16 - Reserved

Customer

ron.pasquarelli 

Priority

(2) Normal 

Service Representative

 

Assigned To

 

Keywords

ESPI; GreenButton; OpenADE 

Comments

No existing entries.

Status

Initiated 

Resolution Type

 

Resolution Date

 

Mark for Knowledge Base

 

Related Articles

 

Resolution Time

Attachments
Version: 1.0 
Created at 9/20/2012 6:36 PM  by ron.pasquarelli 
Last modified at 9/20/2012 6:36 PM  by ron.pasquarelli